A11VLO130DRG Hydraulic Piston Pump
To ensure efficiency and service life, the operating viscosity (at operating temperature) should be selected within the range of 16 ل 36 mm2/s. The viscosity limits are as follows: the minimum viscosity νmin = 5 mm2/s (short time t < 3 min, at the maximum allowable temperature tmax = +115 °C); the maximum viscosity νmax = 1600 mm2/s (short time t < 3 min, during cold start with p ≤ 30 حاجِز, n ≤ 1000 دورة في الدقيقة, tmin = -40 °C). It is only suitable for no-load start-up, and the operating viscosity must be reached within about 15 minutes.