Break-In Procedure: Run at 50% load for the first 20 hours to seat seals and bearings.
Fluid Requirements:
Use ISO VG 46 hydraulic oil with ≤50 ppm water content.
Change oil every 2,000 hours or as per Hitachi’s maintenance schedule.
Torque Specs:
Mounting bolts: 220–240 N·m (162–177 ft-lb).
Drive shaft coupling: 350–380 N·m (258–280 ft-lb).