Break-In Procedure: Run at 50% load for the first 20 hours to seat seals and bearings .
Fluid Requirements:
Use ISO VG 46 hydraulic oil with ≤50 ppm water content.
Change oil every 2,000 hours or as per Hitachi’s maintenance schedule.
Torque Specs:
Mounting bolts: 280–320 N·m (207–236 ft-lb).
Drive shaft coupling: 450–500 N·m (332–369 ft-lb) .