About   Contact    |   

A4VG140 REXROTH A4V A4VG A4VG Hydraulic Pump High Quality A4VG140EP4D132R-NAF02F021DP-S - Tonkee Machinery

Hydraulic Pump/

A4VG140 REXROTH A4V A4VG A4VG Hydraulic Pump High Quality A4VG140EP4D132R-NAF02F021DP-S

A4VG140 Hydraulic Pump

Fluid care: Replace hydraulic oil every 3000–5000 hours (or per fluid manufacturer specs). Use a 10 μm filter cart when refilling to maintain ISO 4406 Class 16/13/10 cleanliness.

Filter replacement: Change the charge filter every 1000 hours and the main circuit filter every 2000 hours. Replace immediately if pressure drop exceeds 1.5 bar.

  • Product Details

A4VG140 Hydraulic Pump

Check charge circuit: Verify charge pump pressure (should be 280 bar continuous). If low, clean/replace the charge filter or repair the charge pump.

Inspect control system: Check the electro-hydraulic proportional valve (E-type control) for power supply or wiring issues. Use a multimeter to confirm 24V DC input.

Check for leaks: Inspect main circuit hoses and fittings—leaks reduce pressure. Tighten fittings or replace worn hoses.

Prev:

Next:

Leave a Reply

Leave a message