Oil change: 1,000 horas de funcionamiento
Filter replacement: 500 horas (suction filter: 1Riñonal-0710; return filter: 1Riñonal-0716)
seal kit replacement: 8,000 horas (kit part: 118-7085)
Inspection Points:
Check for leaks at port connections (SAE 3000 psi flanges: 1½” inlet, 1″ outlet)
Monitor swashplate movement (should be smooth, no binding)
Verify charge pump pressure (minimum 15 bar / 218 psi at idle)